Bioinformatics, PU

Wetlab

Many liquid substances that are handled in a wet lab will be chemicals or hazardous products, which is why a wet lab is set up much differently than a dry lab. These rooms have been designed and built to avoid potential issues that could be caused by spillage and contamination.

Biacore SPR 3000

Surface plasmon resonance (SPR) allows real-time, label-free detection of biomolecular interactions. SPR occurs when polarized light strikes an electrically conducting surface at the interface between two media. This generates electron charge density waves called plasmons, reducing the intensity of reflected light at a specific angle known as the resonance angle, in proportion to the mass on a sensor surface.

Biacore SPR systems are used primarily in pharmaceutical development, quality control, and basic life science research.

 

AKTA HPLC Purifier System

High Performance Liquid Chromatography system.
Different types of ion exchange columns are available for eluting the protein sample. HiTrap – CM Sepharose (5ml), HiTrap – CM Sepharose (5ml), DEAE sepharose (30ml), Size Exclusion column, etc., are few examples among the columns we have. HPLC is connected with the dedicated PC for automated control.

-80C Deep Freezer Premium Upright Model: U410

The freezer shows programmable controls. The interior stainless steel shelves can be easily cleaned. There are four interior compartment doors and five door option. The temperature ranges around -50C to -86C. The capacity is 13 cu ft or 368.1 liters with a RTD control monitor probe that works with the controller to maintain stable freezer temperature.

-20C Deep Freezer Carrier Model HF300

We have a -20C deep freezer for regular storage of protein samples for proteomics and molecular biology work. There are no compartments found apart from a small shelve. The temperature ranges from -4C to -20C.Designed for high ambient. Outer casing is galvanized steel with baked-on paint finish for durability. Inner liner in stucco aluminium(Rust free and Hygienic). R134A Refrigerant -CFC Free. Skin condenser, Auxiliary condenser for better cooling Puf insulation of 60mm thickness for higher retention of cooling inside the freezer. Energy saver compressor -Danfoss make. 4-star rating(Highest for freezer) Higher capacity system for fast pull-down of temperature.
and Adjustable thermostat.

Cooling Centrifuge Relolutionary table top REMI Model: C24BL

The REMI cooling centrifuge has a maximum speed of 6000 RPM at 10 tube of 15 ml total square body, with lid lock and speed control by analogue. It also has a digital display of timer and the timer time has 0-60 minutes speed in digital display. Auto off lid open along with lid breaking system is provided. The power consumption is 500 watt and the requirements include 220V and 50 to 60 Hz.auxiliary laboratories in industry, Educational & Research institutions, Bio Technology, Medical Laboratories, Hospitals, Blood Banks, Pharmaceutical laboratories etc. User can select models as per their requirements from C-24 BL in table top design & C-30 BL a compact high¬speed high volume floor standing centrifuge. salient features are Stepless speed regulator with zero start interlock Digital speed indicator, Dynamic brake, 0-99 minutes digital count down timer, Imbalance cutout, Digital Temperature controller cum indicator

ELISA Reader Versamax Model 2020

It is provided with a 96 wells microplate with a wavelength range of 400-750 mm. the measuring range for the instrument is 0-4.000 Abs and the measuring time is about 3 seconds per plate in a continuous mode. It supports the absorbance, dual wavelength and multi wavelength methods. Using a monochromator-based wavelength selection, wavelength can optimized for visible absorbance between 340 nm and 850 nm. Monitor temperature-sensitive reactions with consistent temperature regulation from ambient to 45°C. SpectraTest® ABS1, FL1, and LM1 Validation Plates tools are available to validate absorbance, fluorescence, and luminescence modes. Reader supports Cell viability, proliferation, and cytotoxicity, ELISAs and immunoassays, Endotoxin detection, Enzyme assays, Protein quantitation Microbial growth, Phosphotases/kinases, Reporter gene assays. SoftMax Pro software is used and it specifies Simple set-up and automatic instrument recognition, wide variety of scan types: Endpoint, Kinetic, Spectrum and Well Scanning, Automatic data recovery feature.

Gel Documentation System Syngene GBOX/EF

It Has a UV-to-white light converter for viewing protein gels. It has a microprocessor based controller with an electromagnetic door latch supported by an electronic door lock with security function to prevent interruption to long exposure. There is high resolution cooled camera for noise free images with 5.5 effective mega pixels. Neutral field screens to automatically eliminate uneven light illumination and lens distortion effects. Captures and analyzes images stained with Ethidium Bromide, Silver stain and Comassive Blue. G:BOX F3 has a high resolution 3.8m pixel camera. The G:BOX F3 can be used with different transilluminator options – either a 302nm transilluminator for all UV applications or an UltraBright-LED “blue” model which is perfect for all “safe” dyes. The software Genesys is the application driven control software which has applications such as fluorescence, chemiluminescence and chemifluorescence. camera control, exposure time, sensitivity setting, lighting requirements, lens control, filter selection- all of this is taken care of by GeneSys.

Refrigerated Centrifuge 5415 Eppendorf

Table top centrifuge with a total volume of 500ml. It serves a temperature range of -9C to 40C. The fixed angle and swing out rotor helps in accommodating both bottom tubes as well as falcon tubes. The swing out rotor also accommodates 36 of 15ml falcon tubes or 48 of 15ml round bottom. Short spin with selectable rotational speed is one its features. Separate rotors for 1.5 – 2.0ml eppendorf tubes are found. A maximum of 12,000rpm is the rotation capacity. The Centrifuge 5415 D is a non-refrigerated bench-top centrifuge and the Centrifuge 5415 R is a refrigerated bench-top centrifuge. Both are used in research and routine laboratories in the biosciences, industry, clinics and chemistry. With their space-saving design and user-friendly operating concept, these centrifuges are ideal for everyday routine tasks. In both devices 24 or 36 Eppendorf micro test tubes can be centrifuged simultaneously in a 45° fixed-angle rotor at 16,100 rcf (13,200 rpm). The basic functions can be selected using the “SHORT” key and the “TIME” and “SPEED” dial. The values appear in the display in digital form